HP900C/HP900C-RM(10~20KVA) 1:1 Phase

  • Application
  • Features
  • Specifications

 

Application:
Server and other networking equipment.

 

 

Features:

Three phase in, one phase out
High frequency and double conversion on-line technology
Fully digitized microprocessor control
Wide input voltage range
LCD display
Cold start
Parallel capacity
Advanced battery management
Automatic battery charge in UPS off mode
Lightning and surge protection
Short circuit and overload protection
Fan speed auto control when loads varies
Optional extension battery pack
EMI/RFI noise filter
Smart RS232 communication with monitoring software
Optional SNMP Card slot

Model HP3910C HP3915C HP3920C
Capacity 10KVA/7KW 15KVA/10.5KW 20KVA/14KW
Input Voltage Range 304±5VAC~478±5VAC
Frequency Range 46~54Hz±0.5Hz or 56~64Hz±0.5Hz auto sensing
Phase Three phase
Power Factor ≥ 0.95
Output Voltage Range 220Vac±1%
Phase Single phase
Frequency Range 50Hz/60Hz±0.2%(battery mode)
THD (linear load) <2%
THD (non-linear load) < 6%
Overload Capability 105%~130%, 10min turn to bypass mode;
>130%, 1s turn to bypass mode
Crest Factor 3:1(max)
Short Circuit Protection 5 cycles turn off inverter, no transfer to bypass, provide alarm (AC mode)
5 cycles turn off inverter, provide alarm (battery mode)
input fuse blown or breaker action (bypass mode)
Waveform pure sine wave
Transfer Time Between AC Mode and Battery Mode 0ms
Transfer Time Between AC Mode and Bypass Mode 0ms
Efficiency ≥ 88%
Battery Model 12V sealed lead acid maintenance free
DC Voltage 240VDC
Configuration 20×12V/7AH External battery bank
Backup Time ( half load ) 13min Depends on the external  
Backup Time ( full load ) 5min battery capacity
Charge Current(standard unit) 1A   N/A
Charge Current(long time unit) 5A
Recharge Time 90% capacity after 8 hrs charging
Communication Interface RS232 ; SNMP (optional)
Parallel port Parallel availability for redundancy and load sharing up to three units
LCD Indication 1, Input voltage/frequency, battery voltage, output voltage/frequency, load watt/VA value and percent, inverter temperature
2, Operation mode such as “on line”, “on batt”, or “or bypass”
LED Indication 1, Green LED for normal operation,
2, Yellow LED for warning condition
3, Red LED for abnormal operation
Noise Level <55dB
Environment Temperature 0~40
Humidity 0%~95% (non-condensing)
Altitude <1500m
Storage Temperature 0~40
Other Standard Unit Net/Gross Weight (kg) 92/107kg N/A
Long Time Unit Net/Gross Weight (kg) 36/46Kg 56/65Kg
Unit Dimension (W×D×H) mm   270×570×720
Packing Dimension   (W×D×H) mm   370×670×940

Wadi Chahrour

Main Road - Farah Bldg

TEL: 05 943020

FAX: 05 943050

Mobile: 03 814572-3-4

ups@propower.cc

Copyright © 2010 Pro Power Equipment All rights reserved Developed by Digital Mirror.